Results: CSTR

Model of a continuous stirred-tank 

reactor (CSTR):

Feedback control system;

Bidirectional dependencies;

Unmeasured variables;

Faults that affect multiple variables 

at once. 

Faults were introduced in:

Heat transfer coefficient;

Discharge coefficient.

Simulation conditions:

False Alarm Rate of 1 %;

Detection Rates were determined 

for on 100 replications;

Each replicate has 5000 

observations.

Figure 1. Diagram of the CSTR process.